How does a level switch work? The diaphragm switch step by step
There are several types of level switch. This article explains the mechanical diaphragm switch, which is how Elniva switches work. It has no electronics and no setting, and that is what makes it simple to install and maintain.
The parts
- A rubber diaphragm, clamped between a mounting ring and a pressure plate, facing the material.
- A microswitch behind the diaphragm, operated by a lever.
- A die-cast light-metal housing with a PG11 cable gland.
- An air filter (NV14P, NV10P) or a compensation diaphragm (KM versions) that lets the space behind the diaphragm equalise with the surroundings.
Step by step
- The silo fills and the material reaches the switch.
- The material presses against the diaphragm.
- The diaphragm moves inwards and pushes the microswitch lever. The travel is limited to 3–4 mm, so the internal parts are protected even under high material pressure.
- The microswitch changes over. The contact (125 VAC / 15 A or 24 VDC / 0.5 A) stops a conveyor, raises an alarm or signals the PLC.
- When the material level falls, the pressure goes, the diaphragm returns and the contact changes back.
Why there is nothing to set
The switch reacts to pressure, not to a property of the material. Moisture, dust and a change of material do not affect when it trips. That is the main difference from capacitive probes and vibrating forks, which are set up for a particular material and condition.
Silo or conveyor
The NV14P has a large diaphragm for silos and bins. The NV10P has a small diaphragm that needs a distinct force to trip, so it ignores normal flow on a conveyor and only reacts when material backs up. Both come in KM versions with IP65 for damp conditions or mounting inside the material.
Full data on the technical facts page.
Tell us the material and where the switch will sit, and we will recommend a model: info@levelswitchsweden.com or +46 8 32 33 00.