Overfill protection in feed and grain plants: where the switch should sit
A grain plant or feed mill has more level points than most people count. Here they are in order, with what each one needs.
1. Intake pit
A high level alarm stops the intake before the pit overfills when the elevator cannot keep up. An NV14P in the pit wall, where the material builds up against the wall, does the job.
2. Elevators and screw conveyors
This is where damage actually happens. If a stop further along makes the material back up, the conveyor keeps running into it, with broken chains, burnt motors and half a day's downtime as a result.
The NV10P is designed for exactly this. It is a compact switch with a small diaphragm that needs a distinct force to trip, which is the point: it does not react when material passes normally, only when it builds up against the switch.
3. The dryer
Dryers need both high and low level. The high level prevents overfilling; the low level prevents drying a half-empty section and scorching the grain. Check that the switch position stays within +60 °C.
4. Storage silo
High level against overfilling, low level to know when it is time to refill. Allow for the angle of repose: the material forms a cone when filled and a funnel when emptied, so the switch should sit where the material rests against the wall, not where the top or bottom stands in the middle.
5. Dosing and finished-product bins
Powdered feed components, premix and mineral blends stick and build up coating. This is where capacitive probes most often start giving false alarms. A diaphragm switch does not care about coating as long as the diaphragm can move, and needs no recalibration when the recipe changes.
In damp positions, or where the switch has to sit inside the bin, choose the KM version with compensation diaphragm and IP65.
Wiring
The microswitch is rated 125 VAC / 15 A or 24 VDC / 0.5 A and gives a volt-free contact. It goes directly into an existing control system or PLC input without an interposing relay, and there is nothing to configure at commissioning.
Summary
| Position | Model |
|---|---|
| Intake pit, dryer, storage silo, dosing bin | NV14P (IP54) or NV14P-KM (IP65, inside mounting) |
| Elevator, screw and belt conveyor | NV10P (IP54) or NV10P-KM (IP65) |
Elniva switches are for dry bulk solids only. They are not for liquids or pressure vessels, and they are not ATEX certified. In dusty areas with a risk of dust explosion, check the zone classification before choosing a switch.
Tell us the material and where the switch will sit, and we will recommend a model: info@levelswitchsweden.com or +46 8 32 33 00.