Plug chute switch for screw conveyors: where it sits and what it stops
A screw conveyor does not stop pushing when its outlet blocks. The screw keeps feeding material back into the trough until something gives: the motor protection trips, the trough packs solid, or a bearing or drive is damaged. A plug chute switch cuts the feed before it gets that far.
Why screw conveyors block
- The receiver is full: the silo, bin or conveyor after the screw cannot take more.
- The material clumps. Damp or frozen material sticks in the outlet, which is more common in winter.
- A foreign object, such as a stone, a piece of twine or a lump of wood, blocks the outlet.
Where the switch should sit
The switch goes where material starts to build up when the outlet is blocked: in the wall of the outlet chute just above the outlet, or in the receiving bin. As material builds up, it presses on the diaphragm and the switch changes over. If the switch sits too far from the outlet, the screw has time to pack the material before the switch reacts.
How it is wired
The switch has a volt-free changeover microswitch (125 VAC / 15 A or 24 VDC / 0.5 A). It is wired into the screw's control so that the screw stops when the switch changes over. If a conveyor or another screw feeds into it, stop that too, or the problem just moves one step back. The switch gives a limit signal, on or off; it does not measure a level.
Test it at the winter service
Run a function check as described in how to test a level switch and confirm that the screw actually stops, not just that the alarm comes on. That shows the whole chain works, from switch to contactor.
Cold rooms and dust
The operating temperature is +1 to +60 °C. If the screw sits in an unheated room that gets colder than that in winter, mention it when you contact us. Our switches are not ATEX certified; in dusty environments, check the zone classification before installing.
Which switch
The Mobrey NV10P and NV14P sit in the wall, outside the material. The KM versions can sit inside the material. More on conveyors in conveyor feeding a full silo: three causes of stoppages and grain handling: protect elevators and conveyors from choke-ups.
Describe the material and the mounting position and email info@levelswitchsweden.com or call +46 8 32 33 00.